snctl firmware command group.
Key concepts
Read this section once. Everything after it depends on these six things.Prerequisites
Firmware commands authenticate to the target devices, so device credentials must be registered first. See Device credentials.Which device types support what
Not every component that can be audited can be upgraded through SambaRack Manager.Choosing a target
Either
--rack-id or --group must be specified. They are mutually exclusive. Both subcommands accept either one.(Optional) Slotted device types and --index
xrdu and card are slotted — they have multiple instances per node, so --index can narrow the operation to specific slots. Pass a comma-separated list, for example 0,2,5.
XRDUs flash two components
Each XRDU contains two independently flashed components — OBMC and RDU-C. They are reported separately byfirmware version, and both must be supplied separately when passing images manually.
Where firmware images come from
The cache directory is shown as Cache Location in
snctl config show. Change it with snctl config update --cache-location <dir>. See Initial setup.
Check firmware versions
Audit installed firmware against the plan of record (POR).Reading the output
FAIL means the firmware is out of date — not that the command failed. The check ran successfully and correctly reported a version mismatch.Wide output
-o wide adds Protocol, Model, and Source columns. Source is the artifact URL of the POR firmware, which you need for airgapped upgrades:
Upgrade firmware
Push firmware to a rack’s components.Recommended order and pre-conditions
There is no strict dependency across the supported components. However, when upgrading more than one, use this order: CARD → BIOS → BMC → XRDUVerifying an upgrade. Run
snctl firmware version --rack-id <rack_id> --device-type all about 5 minutes after a successful run to confirm the new version took effect.Examples
Progress output
Each component reports staged progress as it flashes, followed by a per-component result list and a summary. Components already at the target version are skipped.Airgapped environments
If your environment has no GCS access, supply the firmware file yourself with--image.
1
Look up the download URL
Run
firmware version -o wide and read the Source column for the component you are upgrading:2
Download the file out of band
From a host that does have GCS access, download it and transfer it into the airgapped environment:
3
Pass the local path
Image path format
Upgrade procedures by device type
Follow these in the recommended order when upgrading more than one component. CARD → BIOS → BMC → XRDUCARD (Thor NIC)
Pre-condition: the SambaNova driver daemon (snd) must be active on the host. SambaRack Manager waits for this automatically before flashing, so no manual check is required.
No power cycle is required for CARD upgrades —
bnxtnvm flashes take effect without a reboot. This is the one upgrade target that does not need a power operation afterward.BIOS
Pre-condition: the host must be powered on.1
Confirm the host is powered on
2
Run the upgrade
3
Power off the node, then bring the host up alone
Omit Then power on the host by itself. The new BIOS is applied during POST — the console shows the BIOS settings being applied, and the host may reboot once on its own before booting to the OS.
--type so both the host and the XRDUs power off:Wait 10–15 minutes after power-on for the host to finish POST and boot to the OS before continuing.
4
Confirm SR-IOV is disabled
SR-IOV must be disabled in the BIOS. The relevant attribute is The BMC password comes from the secret store:Use these values for Apply the change by cycling the host again:Wait 10–15 minutes for the host to boot, then re-check
PCIS007. These checks run over Redfish, directly against the BMC.Gather the BMC connection details. The BMC IP and username come from the node’s inventory — read them from the BMC row:<bmc_ip>, <bmc_user>, and <bmc_password> below.Check the current value:- Reads
"Disabled"— continue to the next step. - Reads anything else — disable it below.
PCIS007 and confirm it now reads "Disabled" before continuing.5
Power cycle the entire node
Only once SR-IOV is confirmed disabled.
snctl power cycle always targets the whole node, so there is no --type flag.6
Verify the firmware version
BMC
Pre-condition: the host must be powered on.1
Run the upgrade
2
Power cycle the node, then verify
XRDU
Pre-condition: the host must be powered off — the opposite of the BIOS pre-condition.1
Confirm the host is powered off
2
Run the upgrade
Both components (OBMC and RDU-C) are upgraded together.Remember that this powers off all XRDUs on the node, regardless of any
--index you pass.3
Power the node back on, then verify